Component Tests and General Diagnostics
RESISTANCE CHECK- Disconnect the sensor harness connector.
- Measure the resistance between terminals (5 - 6) and (5 - 1) of the air mass sensor.
5 - 6 Resistance = approximately 3 - 4 Ohms
5 - 1 Resistance = approximately 16.3 kOhms
If not, replace the air mass sensor.