Rear Defogger: Description and Operation
OperationWith the IHKR2/3 switched on and the engine running, when pressed for the first time, the rear window defogger button switches on the rear window defogger (defrost stage). The function indicator lamp lights and the defrost time counts down from 600 seconds to 0 seconds.
After the defrost time has elapsed, the function LED goes out and the rear window defogger is switched off for 80 seconds and switched on for 40 seconds.