Code 07 (Evaporator Sensor)
^D^900 Defect Code Memory: 07 Evaporator SensorExplanation:
This defect code is stored when a short to ground, short to positive, or a break is detected at blue connector Pin 9.
Effect of defect:
If the defect is a current defect, a substitute value of 25°C (75°F) is used.
Possible cause:
Wire or evaporator sensor defective.
Troubleshooting:
Check wires and repair if necessary, or renew component.