Code 07 (Evaporator Sensor)
^D^ Defect code memory: 07 Evaporator SensorExplanation:
This defect code is stored when there is a short to ground, to positive, or a break at blue connector Pin 9.
Effect of defect:
If the defect is a current defect, a substitute value of -5°C (23°F) is used.
Possible cause:
Voltage supply (approximately 5V) not OK, wire or evaporator sensor defective.
Troubleshooting:
Check voltage supply (approximately 5V with temperature sensor disconnected) as well as wires and repair or renew component as required.