Code 47 (A/C Decoupling Relay)
^D^ Defect code memory: 47 A/C Decoupling Relay - DME/EML
Explanation:
This defect code is stored when there is a short to ground. to positive, or a break at white connector Pin 6.
Effect of defect:
If the defect is a current defect, the component is no longer activated.
Possible cause:
Wire or auxiliary fan relay defective.
Troubleshooting:
Check wire and repair or renew component as required.