Defect Code 47
Defect Code 47:
*D* Defect code memory: 47 Decoupling relay DME/EML:
Explanation: This defect code is stored when there is a short to ground, to plus or a break at connector white Pin 6.
Effect of defect: If the defect is a current defect, the component is no longer activated.
Possible cause: Wire or decoupling relay defective.
Troubleshooting: Check wire and repair or replace component as required.