Code 36 (Canister Purge Control)
TANK VENTILATIONExplanation
This trouble code is stored in the case of a break or short at:
- Fuel evaporation purge control valve
- Wire from Digital Motor Electronic (DME) control unit to fuel evaporation control valve
- Output stage in the DME control unit
Effect of Defect
- Short to ground: No fuel evaporation control since the solenoid valve remains closed.
- Short to positive (or break): The solenoid constantly remains open. As a result, the fuel vapors supplied via the fuel evaporation control valve can lead to malfunctions when idling and during acceleration.
NOTE: During normal operation, the valve is opened dependent on engine speed and load.
Troubleshooting
Activate the purge valve with tester. The valve is activated at 1 second intervals - this is audible.
Does the fuel evaporation control valve respond?
- YES: Check wire and connector or loose contact.
- NO: Connect test lamp (12 V 10 W) and activate component.
Does test lamp flash?
- YES: Check function of fuel evaporation control valve, see test instructions.
- NO: Check voltage supply at fuel evaporation control valve. Check wires.
- Check output at DME control unit (Pin 36).
- Proceed with displayed scan tool diagnostic instructions where applicable.