Operation CHARM: Car repair manuals for everyone.

Celsius to Fahrenheit Display



This article has been updated by technical service bulletin (TSB) 62 02 97 dated December 1999 (originally published in 1997).

ALLDATA Editor Note: Please verify that the temperature displayed is a setting, and not a readout of ambient temperature, as ambient temperature is a function of the Trip Computer (Accessory) or the On Board Computer (Optional Equipment). Please refer to Accessories and Optional Equipment / Trip Computer for more information. Trip Computer

E36 IHKA production dates and model year information.:










The E36 IHKA control panel/module includes additional programming that allows system diagnosis without the use of the DIS or MoDiC; sensor values and other inputs are shown on the LCD display. This function is found on systems produced from 12-95 through 3-97.


Temperatures are always shown in degrees Celsius, regardless of module coding. Blower speed cannot be adjusted during sensor display mode.






Control Panel/Module Coding

The IHKA control panel/module is coded with the central coding key (ZCS) using the OE Diagnostic Tool. The ZCS coding procedures is the same as on previous systems.

After coding a new or replacement control module, disconnect it from the battery completely (unplug the control module from the vehicle wiring harness) for a minimum of 10 seconds. This allows the new coding data to overwrite any previous coding data.







Coding Conversion Features




Coding conversions provide flexibility for various system functions and allow a vehicle owner to customize the car's climate control system.

The E36 IHKA is capable of the following conversions:

- Temperature C/F
- Blower enhancement - increase the blower default speed (only possible from software version 37, introduced September 1995)
- Air recirculation - retain the recirculate air function for use at restart.