Independent Ventilation
Independent ventilationThe independent ventilation function can be activated in ignition lock position OFF or in ignition lock position terminal R by means of the multi-information display (MID). Various settings are possible dependent on the ignition lock position.
Statuses at ignition lock terminal R:
Operating unit is active
Temperature control not active (water valves closed)
Flap program is adjustable
Blower is adjustable
Function lights ON
Button block not active
Statuses at ignition OFF:
Operating unit not active
Temperature control OFF (water valves closed)
Fresh air flap position 100%
Recirculated air flap position 0%
Mixing air flap position 0%
Defrost flap position 0%
Ventilation flap position 100%
Footwell/rear area flap position 0%
Rear area ventilation flap position 0%
Function lights OFF