Computer/Controls - DME Module Removal Precautions
Group 12Engine Electrical
Bulletin Number
12 11 00
Woodcliff Lake, NJ
October 2000
Service Engineering
This bulletin is also issued in Group 24 (Automatic Transmission), S.I. 24 10 00, the contents of which are identical.
SUBJECT:
MS43 DME Removal Precautions - EGS Failure Avoidance
MODEL:
All with MS43 control unit
Situation:
The MS43 control module may stay "alive" after the key is off, due to the DM-TL test.
If the following procedure is not followed, irreparable damage to the EGS control module will occur.
PROCEDURE
1. Always verify that the ignition key is in the "off" position before disconnecting the DME.
2. Allow, at least, 3 minutes to elapse, after the key was set to the "OFF" position before disconnecting the DME. This will allow for sufficient time to complete the DM-TL test.
WARRANTY INFORMATION: For information only