Operation CHARM: Car repair manuals for everyone.

Technical Data

Oil Volume in Hydraulic Circuit 1.2 ltr
Ratio 14.5
Friction Torque Outside of Pressure Point Measured on: Steering Gear Standard 0.65 - 0.90 Newton Meter (Nm)
Servotronic 1.0 - 1.25 Newton Meter (Nm)
Friction Torque at Pressure Point Measured on: Steering Gear Standard 1.10 - 1.30 Newton Meter (Nm)
Servotronic 1.40 - 1.60 Newton Meter (Nm)
Rated Pressure with Engine Running at Idling Speed Impeller Pump 130 - 140 Bar (bar)