Antitheft System - Diagnostics Cannot Be Accessed
SI B 65 07 06Sound System, Cruise, Alarms, Monitors
April 2006
Technical Service
SUBJECT
DWA Diagnostics Cannot be Accessed
MODEL
E53 (X5)
SITUATION
The DWA (Alarm System) test plan cannot be accessed, even if a DWA fault is stored.
CAUSE
Fault in the diagnosis test module in DIS V44.0 and V45.0
PROCEDURE
As a work-around, select "Function Selection / Complete vehicle / Body / Locking and Security / Power windows", then press the forward green arrow.
Select "Power Windows" from the test plan, then forward with the green arrow until the diagnosis menu screen shows that has the selection "8 - Burglar alarm system (DWA)"
Select "Burglar alarm system (DWA)" and press the forward green arrow to enter DWA diagnostics.
A corrected DWA test plan will be released with DIS V46.0, expected June 2006.
WARRANTY INFORMATION
Information only