Replacing Pulse Generator (Output Speed)


Note: After completion of work, check transmission fluid level.

Caution!
^ Use only the approved transmission fluid in this automatic transmission.
^ Failure to comply with this requirement will result in serious damage to the automatic transmission!

Remove and install transmission fluid sump, refer to Fluid Pan, A/T, Service and Repair.





Disconnect plug (1).

Release screw (2).

Tightening torque, refer to Specifications.

Withdraw pulse generator (3).

Read out fault memory of EGS control unit.

Check stored fault messages, eliminate faults and then clear fault memory.