Replacing Pulse Generator (Output or Turbine Speed)
Replacing Pulse Generator (Output Or Turbine Speed)
Remove valve body.
Refer to 24 30 006
Impulse sensor for output speed:
Pull off plug (1).
Remove screws (2 and 3).
Installation:
Tightening torque, refer to Technical Data 24 34 4AZ
Lift off pulse sender.
Caution: Watch out for spacers (4 and 5).
Impulse sensor for turbine speed: Pull off plug (1). Remove screws (2 and 3).
Lift off pulse sender.
Installation:
Tightening torque, refer to Technical Data 24 34 4AZ