Crankshaft Position Sensor: Service and Repair
Replacing Pulse Generator On Crankshaft (S54)
Turn off ignition.
Remove reinforcement plate on front axle support.
CAUTION: The section "Removing and installing reinforcement plate on front axle support" contains important installation instructions.
NOTE: Installation location of pulse generator for crankshaft is underneath starter motor.
Unlock plug (1) and detach from distributor housing (2).
NOTE: For a better overview, the intake air manifold is not shown.
Release screw.
Unclip cable of pulse generator (1) from holder (2).
Remove pulse generator (1).
NOTE: For a better overview, this work step is shown on an engine that has been removed and without the starter motor.
NOTE:
Interrogate fault memory of DME control unit.
Check stored fault messages.
Rectify faults.
Then clear fault memory.