Operation CHARM: Car repair manuals for everyone.

Initial Inspection and Diagnostic Overview




37 10 001 - Initial operation with test run of Dynamic Drive





Note:
The Service function Initial operation of Dynamic Drive must be carried out after:

- Work on the Dynamic Drive system which involved opening hydraulic lines
- Replacement/Programming/Coding Dynamic Drive control unit
- Replacement lateral acceleration sensor
- Parameters and zero point of new sensors have been learned





Bleeding power steering:

Important!
Adhere to the utmost cleanliness. Do not allow any dirt to enter the hydraulic system.
Using contaminated equipment to add fluid may introduce dirt particles into the fluid reservoir and significantly reduce the service life of the power steering system. Do not use any filler funnels or similar!
Use only Pentosin CHF11S from original containers!
The fill level may only be checked or adjusted when the engine is stopped! The fluid temperature should be approx. 20° C here.
Ensure that the cap is fully screwed in prior to the fill level check.





Note:
To avoid mix-ups when filling with hydraulic fluid, mark the fluid reservoirs or their caps with identification marks.
CHF - Pentosin CHF11S





1. Thoroughly clean fluid reservoir and its immediate surroundings
2. Check and correct fill level
Note: The fill level can come to rest above the "MAX" mark when the engine is at normal operating temperature. This is dictated by the design in that the marking on the dipstick is referred to a fluid temperature of 20° C. With the engine at normal operating temperature (approx. 50 - 60° C fluid temperature) adjust a fill height 15 mm above the "MAX" mark. Do not under any circumstances draw off the fluid to the "MAX" mark when the engine is at normal operating temperature.
Hydraulic fluid: BMW Service Operating Fluids
3. Start engine
4. Turn steering wheel left and right twice in each case up to full lock; if necessary, top up hydraulic fluid (e.g. if hydraulic system is completely drained)
5. Move steering wheel to straight-ahead position and turn off engine
6. Check and correct fill level with engine stopped
7. Check hydraulic system for leaks





Performing initial operation with test run:

Warning!
Risk of injury!
Vehicle executes heavy rolling motions during initial operation! Therefore observe the following instructions without fail:
- Do not allow any persons to remain in the vehicle or directly on the vehicle
- Keep the vehicle doors closed.
- Maintain a safety distance around the vehicle of 1 m to persons, objects, walls etc.
- Vehicle must be standing horizontally with all wheels on a firm surface
- Do not under any circumstances carry out initial operation on a lifting platform, wheel alignment analyzer or similar!
- Avoid heavy loads





1. Check load; if necessary, remove load from the vehicle
2. Bring engine up to operating temperature
Note: Hydraulic fluid temperature must be between 50° C and 70° C (vehicle at normal operating temperature)
3. Connect vehicle to DIS or MoDiC
4. Start initial operation in SERVICE FUNCTIONS. Follow instructions in DIS.
5. Check and correct fill level with engine stopped