Antitheft System - No Start After EWS Calibration
SI B 61 24 06October 2006
General Electrical Systems
Technical Service
This Service Information bulletin supersedes S.M. B61 202 03 dated October 2003.
SUBJECT
Starts only once following EWS calibration
MODEL
E60 (5 Series) Since start of series production to August 15, 2003
SITUATION
The vehicle does not start. The starter motor turns briefly, and then the fault message "DME 4A61 EWS manipulation" is entered in the fault memory.
CAUSE
The bolt connection on the wiring harness tapping (100 A fuse) for the battery positive lead (B+) is loose.
PROCEDURE
Tighten the bolt connection for the "B+" wire to torque