Operation CHARM: Car repair manuals for everyone.

A/C - Blower Motor Stays ON With Key OFF/FC 2DED Set

SI B 64 01 06
September 2006

Heating and Air Conditioning
Technical Service

This Service Information bulletin supersedes S.I. B64 01 06 dated January 2006.

[NEW] designates changes to this revision

SUBJECT
Blower Motor Stays On with Key Off

MODEL
E60, E61 (5 Series)

[NEW] E63, E64 (6 Series)

Vehicles produced up to August 30, 2006

SITUATION
The customer states that occasionally after a long drive, the blower motor stays on at a reduced speed from the last setting on the control panel, for up to 16 minutes after the vehicle was turned off.

DME FC "2DED Battery Power management" may also be stored. This complaint will not cause the battery to be discharged.

CAUSE
Blower motor LIN-Bus communication error (blower in emergency mode).

PROCEDURE
1. Troubleshoot any faults stored in the system. Complete "Energy Diagnosis" test plan if DME FC 2DED is stored.
2. NEW Update the complete vehicle per SI B09 05 01 (Coding, Individualization, Programming) Procedure B, using Progman V23.00.00 (Target Data Status E060-06-09-520) or higher.

WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty.

Defect Code Refer to KSD

Labor Operation: Refer to KSD
Labor Allowance: Refer to KSD