Operation CHARM: Car repair manuals for everyone.

Deactivation, Overtemperature




Deactivation, Excess Temperature

If a control module becomes too hot, this control module switches off for up to 10 minutes to protect the individual components against damage. Furthermore, the entire MOST bus can switch off for 10 minutes. After the control module has cooled down, it regains function!

Bear in mind that the failure of a MOST control module leads to disturbances throughout the entire MOST framework.

Example fault patterns that occur are:
- rhythmic recurring crackling noises in the audio system
- Control Display (CD) remains white or dark, which means that no vehicle functions can be called up via the Control Display.

If the fault "Cutoff excess temperature" is stored in one or more MOST control modules, the following Service Information must be taken into account:
TIS ->Document -> Service information -> Enter SI Number
SI number: 65 16 02942

Top HiFi amplifier: Detection of excess temperature
The Top HiFi amplifier can only disable its own functions at high temperatures. If the customer is currently listening to music, the following fault pattern results:
- Sound failure in the audio system.

The Top HiFi amplifier does not make a fault memory entry. The MOST framework remains functional. After the control module has cooled down, the Top HiFi amplifier regains function!