Lighting - Battery Discharged By Lamp Module
SI B 61 16 06October 2006
General Electrical Systems
Technical Service
This Service Information bulletin supersedes S.M. B61 206 04 dated May 2004.
SUBJECT
Battery Discharged by Lamp Module
MODEL
E65, E66 (7 Series) produced February 26, 2004 to April 18, 2004
SITUATION
Battery discharged, vehicle will not start.
CAUSE
The Lamp Module (LM) sends an incorrect bulb status message to the power module (PM) (i.e. bulbs on even though they are off). The Power Module (PM) is then unable to disconnect and the battery is discharged
PROCEDURE
Code the LM using CIP V 11.2 or a more recent version. Refer to SI B09 05 01 (Coding, Individualization and Programming) procedure.
Disclaimer