Front Door Window Glass: Service and Repair
51 32 170 Removing And Installing / Replacing Door Window Glass, Front Left Or Right
Necessary preliminary tasks:
- Remove window cavity cover strip
- Remove sound insulation
Door window glass (1) must be opened to dimension (A).
A = approx. 110 mm
IMPORTANT: Disconnect plug connection (1) from power window motor (2) (risk of trapping).
Installation:
- Carry out function check on power window unit and anti-trapping protection.
- If necessary, initialize power window.
Release screw (1) through bore on inner door panel (2).
Installation:
Insert door window glass (3) with clamping plate (4) in mounting (5).
2AZ Door window glass to holder 8 Nm
Slide locking clip (1) to one side.
Grip door window glass (4) and detach mounting (3) from power window (2).
Turn door window glass (4) and lift out.
Installation:
Adjust door window glass.
Installation:
Sliding block (1) must be correctly positioned in mounting (2).
Clamping plate (4) must be correctly engaged with slider (3) on door window glass (5).
Replacement:
Lever out catch (2) from shim (4) and remove with clamping plate (3) from door window glass (1).
When replacing clamping plate or slider:
Lever out catches (5) and remove clamping plate (3) from slider (4).