Operation CHARM: Car repair manuals for everyone.

2BAD - P1597 (DME)

2BAD - P1597

Information saved in
DME

Fault code
2BAD - P1597

Fault text
DME2: DME, DME2: hardware, plausibility

Fault description
DME, DME2: Hardware, plausibility

Condition for fault identification
Test condition:
Voltage monitoring at Pin 3-45 must be 0V at the slave and
4.4 V < UBatt < 5.6V at the master control module
Terminal condition: Terminal 15=TRUE
Voltage condition:
9.5 < U < 17.9

Condition for fault memory entry
500 ms

Action in service
Check plug/wiring harness,
check voltage at Pin 3-45,
otherwise replace DME

Fault effect and breakdown warning
none

Driver information
Warning light:
none

Service instruction
none