Computers/Controls - Progman(R) V22.0/V22.0.1 Errors
SI B 09 13 06Programming/Coding Explanation
June 2006
Technical Service
SUBJECT
Release Notes Progman V22.0 and V22.0.1
MODEL
All
SITUATION
Progman V22.0 and V22.0.1 have been released. Certain errors may occur during installation or usage.
CAUSE
Software error
COMPLAINT
The following issues are currently known:
1. "Back" button is missing after the "Change" button in the menu bar has been selected.
2. An incorrect CIP version may be displayed on the "Online update" screen after a JETStream update.
3. It may no longer be possible to use the GT1 after selecting "Update software".
4. In some cases, no status display (white screen) appears for a few minutes if a measures plan is cancelled.
5. No FASTA data has been transferred for a long period of time.
6. SSS enters service mode during the day, and it is no longer possible to start a session.
7. The user interface may show "# 4" following a full installation using Progman V22.0
8. E36: The last digit is not displayed when codes are entered using the virtual keyboard.
9. E36: It is not possible to update the programming of the EPROM (DME MDS41.0 EPROM).
10. E36 / E38 / E39 / E46 / E52 / E53: Retrofits and conversions may or may not be offered on vehicles with ZCS, even if they are not valid for the vehicle concerned.
11. Various errors may occur during replacement procedure on vehicles with ZCS code.
12. E53: Vehicle information may be exchanged between two simultaneous running sessions of same vehicle series with ZCS code.
13. E65/E60/E61/E63/E64: The measures plan states that enabling codes must be imported even though neither the NVE control unit nor the night vision camera need to be re-enabled
14. E85: EPS encoding may not work after programming.
15. E90: service function for "LWS" may not work.
PROCEDURE
1. Button is hidden behind the "Minimize" button, no workaround.
2. Ignore the incorrect CIP version displayed.
3. Proceed as follows: 1. Disconnect the GT1 cable and wait until an error message notifies you of the loss of connection. 2. Reconnect the cable. 3. Update the SSS list. 4. Select the SSS again and
end the session in the usual way.
4. Wait until the next screen appears. This may take a few minutes.
5. Check all FASTA and online service settings. If everything is correct, reinstall Progman. However, the existing FASTA data will be lost.
6. Go to "Operating State" on the SSS, press "Cancel" and wait about 1-2 minutes.
7. Restart the system manually.
8. Ignore the display. Code is still accepted even though it is not shown.
9. No workaround possible.
10. Ignore the retrofit and conversions offered in error.
11. Only one old-series vehicle per SSS should be handled using Progman, especially if a control unit is being replaced.
12. Only program one vehicle of this series per SSS.
13. If night vision camera functions correctly, it is not necessary to import a new enabling code.
14. Reprogramming module.
15. Repeat service function for "LWS"or "LWS"
Additional notes:
All: A MOST connection must be established between the OP(P)S and the vehicle when programming vehicles with a MOST bus.
E65: A battery reset must be carried out after programming a vehicle produced 03/05 or later if CD (Control Display) was part of the measures plan. However, oil level information will then be lost =>
Solution: run the engine at idling speed for 20 minutes.
E65: In isolated cases, the DME control unit for 12-cylinder engines aborts programming with error code "2082 Error clearing flash". This concerns control units with HW* number 7537117 (integration level E065-03-12-500 to E065-05-03-810) and earlier. The control unit then no longer responds.
Workaround: power reset.