Replacing A Front Pulse Generator
Replacing A Front Pulse GeneratorOpen connector housing, pull plug connector out of bracket and disconnect.
Pull cable with rubber grommet out of bracket on spring strut.
Installation: Ensure proper locking of plug connector and proper seating of rubber grommets.
Release hexagon socket head cap screw (1), pull cable out of mounting on spring strut. Pull ABS pulse generator out of hole.
Installation: Clean bore for pulse generator and grease with Staburags NBU 12/K lubricant
- Pulse generator to swivel bearing/wheel carrier 8 Nm