P1504
2AE6 - P1504Information saved in
DME
Fault code
2AE6 - P1504
Fault text
Idle-speed actuator, position CLOSED
Fault description
Idle-Speed Control Valve Closing Solenoid Control Open
Circuit
Condition for fault identification
Test condition:
Idle on
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
20 sec.
Action in service
1) Perform electrical check on switch wires and power-
supply wires
2) Visual inspection of plug-in contacts
(on component and DME sides)
3) Check driver on DME side
Fault effect and breakdown warning
Driver information
Warning light:
NO
Service instruction
none