Condition For Fault Memory Entry - 2
2CA6 - P0135Information saved in
DME
Fault code
2CA6 - P0135
Fault text
Oxygen sensor heating before catalytic converter, function
Fault description
O2 Sensor Heater Circuit (Bank 1 Sensor 1)
Condition for fault identification
Test condition:
Examination of oxygen sensor heater, oxygen sensor fails to
reach operating temperature after start, no fault codes logged
in fault memory
Terminal condition: Terminal 15, engine on
Condition for fault memory entry
O2 sensor temperature of 650 °C not reached by 30 sec.
after engine start
Action in service
1. Visual inspection of wires, DME plug and O2 sensor for
damage
2. Check wires (including resistance)
3. Check plug-in connections DME <=> Wiring harness
<=> Upstream (pre-cat) O2 sensor on Bank 1 (water or
corrosion in the plug? => Repeatedly disconnect the plug
and then FIRMLY press it back in)
4. Replace O2 sensor
5. Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none