67 62 000 Removing and Installing/Replacing Flat Motor For Front Left or Right Power Window Unit
67 62 000 Removing And Installing/Replacing Flat Motor For Front Left Or Right Power Window Unit
Necessary preliminary tasks:
- Remove power window unit in front door
Release screws (1).
Tightening torque 67 62 1AZ.
Detach flat motor for power window unit (2) from power window unit and remove.
Installation:
Fit flat motor for power window unit (2) exactly on teeth of power window unit.
Carry out function check (one-touch function, anti-trapping protection and, if necessary, comfort function).
Replacement:
A normalization must be carried out in order to activate anti-trapping protection.
Operating sequence for normalization:
- Operate corresponding power window switch in "Close" setting.
- Once the upper end position has been reached, hold power window switch down for approx. 1 second more.
Normalization is thus completed.