P129B
2D2B - P129BInformation saved in
DME
Fault code
2D2B - P129B
Fault text
Intake-manifold pressure sensor, overrun
Fault description
Manifold Absolute Pressure Sensor Afterrunning Diagnosis
Range/Performance
Condition for fault identification
Test condition:
in shutdown phase T>2 sec. with NMOT=0
Barometric pressure >750 hPa
-20�< Control module temp.<146�
-20� < Induction air temp. < 100�
Terminal condition: (Terminal 15 or
run-on phase) +
NMOT=0
Voltage condition:
none
Condition for fault memory entry
0.2 sec.
Action in service
1) Check signal path
2) Replace sensor
Fault effect and breakdown warning
Driver information
Warning light:
No warning lamp or CC None status report
Service instruction
none