P0507
2B58 - P0507Information saved in
DME
Fault code
2B58 - P0507
Fault text
Idle controller monitoring
Fault description
Idle Control System RPM Higher Than Expected
Condition for fault identification
Test condition:
RPM too high by 200 rpm (K_LLR_DIAG_N_ZU_GROSS)
and idle controller at lower travel stop for 9 sec.
(K_LLR_DIAG_T)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
9 sec.
Action in service
1. Check for leaks between idle actuator and engine block,
replace gasket as indicated
2. Check individual throttle valves for opening gap
Fault effect and breakdown warning
No closed-loop idle control
MIL after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none