P103E
2764 - P103EInformation saved in
DME
Fault code
2764 - P103E
Fault text
VANOS valve, exhaust, bank 1, activation
Fault description
'B' Camshaft Position Actuator Over Temperature (Bank 1)
Condition for fault identification
Test condition:
Driver diagnosis ATIC35
(temperature violation)
Terminal condition: TERM87
Voltage condition:
Battery voltage > 10V (k_diag_tr_ed_ubmin)
Condition for fault memory entry
Errors recognized 10x consecutively
Action in service
1. Check valve and replace as indicated
2. Check temperature of DME and E-Box
Fault effect and breakdown warning
Reduced torque
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none