P02D4
4B16 - P02D4Information saved in
DDE
Fault code
4B16 - P02D4
Fault text
DDE: Zero-quantity adaptation, injector, cylinder 5:
permissible filtered activation duration correction too low
Fault description
Monitoring zero-quantity delivery rate adaptation.
The diagnostic trouble code is logged when the injector
activation period at one of the 3 calibration points falls
below the maximum activation duration and when the signal
deviation at one of the 3 calibration points exceeds the
signal limit.
Condition for fault identification
Test condition:
Monitoring proceeds in a 100 ms grid.
Voltage condition:
Monitoring proceeds in a 100 ms grid.
Condition for fault memory entry
Event debounced (1)
Action in service
Replace injector.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none