P045B
4DA7 - P045BInformation saved in
DDE
Fault code
4DA7 - P045B
Fault text
DDE: Low-pressure exhaust-gas recirculation controller,
activation: Output stage, overtemperature
Fault description
The DDE recognizes an over-temperature fault in the output
stage:
Low-pressure EGR actuator.
Condition for fault identification
Test condition:
The error check proceeds continuously in the programmed
process grid.
Voltage condition:
The error check proceeds continuously in the programmed
process grid.
Condition for fault memory entry
Debounce (220 ms)
Action in service
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling
are OK:
Replace DDE ECU.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none