4A0E - P064C (DDE)
4A0E - P064CInformation saved in
DDE
Fault code
4A0E - P064C
Fault text
DDE: Glow control unit internal: internal hardware fault
Fault description
Internal malfunction in glow-plug preheating control
module.
The glow-plug preheating control module reports an internal
fault in a LIN message.
Condition for fault identification
Test condition:
The LIN message is transmitted every 500 ms.
Voltage condition:
The LIN message is transmitted every 500 ms.
Condition for fault memory entry
Debounce (1200 ms)
Action in service
Replace glow-plug preheating control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none