P120D
4B72 - P120DInformation saved in
DDE
Fault code
4B72 - P120D
Fault text
DDE: Heating crankcase ventilation, activation: Output
stage, overtemperature
Fault description
The DDE recognizes an over-temperature fault in the output
stage:
Positive crankcase ventilation heater.
Condition for fault identification
none
Condition for fault memory entry
Debounce (220 ms)
Action in service
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling
are OK:
Replace DDE ECU.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none