P122C
475F - P122CInformation saved in
DDE
Fault code
475F - P122C
Fault text
DDE: Nitrogen oxide sensor upstream of SCR catalytic
converter, line disconnection short circuit to ground: Short-
circuit
Fault description
The error is recognized when NOx sensor 1 (before SCR
converter) transmits a short circuit error (linear, binary
lambda value, NOx signal or heater circuit) via the CAN.
This is the case when at least one of the following error
conditions has been recognized:
- NOx sensor short circuit == 1
- Linear lambda short circuit == 1
- Binary lambda short circuit == 1
- Short circuit in heater == 1
Condition for fault identification
Test condition:
The following conditions must be satisfied before the NOx
sensor diagnosis function is enabled == 1
- Heater diagnosis enabled == 1
- NOx sensor heater temperature has reached specified
temperature. == 1
- No electrical malfunctions have been detected is locked.
Voltage condition:
The following conditions must be satisfied before the NOx
sensor diagnosis function is enabled == 1
- Heater diagnosis enabled == 1
- NOx sensor heater temperature has reached specified
temperature. == 1
- No electrical malfunctions have been detected is locked.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
Replace wire (supply NOx sensor ECU or between NOx
sensor ECU and NOx sensor) /check plug and/or replace
NOx sensor 1 (before SCR converter).
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
3. Replace NOx sensor 1 (on front side of SCR converter).