P2009
4141 - P2009Information saved in
DDE
Fault code
4141 - P2009
Fault text
DDE: Swirl-flap actuator, activation: Short circuit to ground
Fault description
The DDE recognizes short circuit to ground error in the
output stage:
Swirl-valve actuator.
Condition for fault identification
Test condition:
The check frequency depends on the process sequence
control.
Voltage condition:
The check frequency depends on the process sequence
control.
Condition for fault memory entry
Debounce (10200 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace swirl-valve actuator.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction