P2010
4130 - P2010Information saved in
DDE
Fault code
4130 - P2010
Fault text
DDE: Swirl-flap actuator, activation: Short circuit to
positive
Fault description
The DDE recognizes a short circuit to positive error in the
output stage:
Swirl-valve actuator.
Condition for fault identification
Test condition:
The check frequency depends on the process sequence
control.
Voltage condition:
The check frequency depends on the process sequence
control.
Condition for fault memory entry
Debounce (220 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace swirl-valve actuator.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none