P2238
49EF - P2238Information saved in
DDE
Fault code
49EF - P2238
Fault text
DDE: Oxygen sensor, signal pump current, Nernst voltage
or virtual mass: Short circuit to ground
Fault description
The DDE recognizes a short to ground at the output stage:
Oxygen sensor wiring.
Condition for fault identification
Test condition:
The following conditions must be met for the error check:
- No internal errors may be present in the output stage.
- The open-circuit diagnosis is not active.
Voltage condition:
The following conditions must be met for the error check:
- No internal errors may be present in the output stage.
- The open-circuit diagnosis is not active.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace oxygen sensor.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none