P229E
4744 - P229EInformation saved in
DDE
Fault code
4744 - P229E
Fault text
DDE: Nitrogen oxide sensor downstream of SCR catalytic
converter, line disconnection short circuit to B+: Open
circuit
Fault description
The error is recognized when NOx sensor 2 (behind SCR
converter) transmits a load drop error (linear, binary lambda
value, NOx signal or heater circuit) on the CAN.
This is the case when at least one of the following error
conditions has been recognized:
- NOx sensor wire open == 1
- Linear lambda wire open == 1
- Binary lambda wire open == 1
- Open wire in heater == 1
Condition for fault identification
Test condition:
The following conditions must be satisfied before the NOx
sensor diagnosis function is enabled == 1
- Heater diagnosis enabled == 1
- NOx sensor heater temperature has reached specified
temperature. == 1
- No electrical malfunctions have been detected is locked.
Voltage condition:
The following conditions must be satisfied before the NOx
sensor diagnosis function is enabled == 1
- Heater diagnosis enabled == 1
- NOx sensor heater temperature has reached specified
temperature. == 1
- No electrical malfunctions have been detected is locked.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wiring and plug-in connections (power supply to
NOx sensor control module and NOx sensor).
2. Replace NOx sensor 2 (behind SCR converter).
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none