P0131
2C3F - P0131Information saved in
DME
Fault code
2C3F - P0131
Fault text
DME, internal fault: oxygen sensor, evaluation module
Fault description
O2 Sensor Circuit Low Voltage (Bank 1 Sensor 1)
Condition for fault identification
Test condition:
Monitoring of O2 sensor chip
No fault memories
Terminal condition: Terminal 15, engine on
Voltage condition:
none
Condition for fault memory entry
Short to ground in self-diagnosis processor chip
Action in service
1. Visual inspection of wires, DME plug and O2 sensor for
damage
2. Check wires
3. Check plug-in connections DME <=> Wiring harness
<=> Upstream (pre-cat) O2 sensor for Bank 2
4. Check wiring harness for shorts to positive or ground and
shorts/shunt to other bank (melted?) => Replace wiring
harness
5. Replace O2 sensor
6. Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none