P116C
2D0F - P116CInformation saved in
DME
Fault code
2D0F - P116C
Fault text
Air-mass sensor, signal
Fault description
Air Mass Flow Sensor Signal Range
Condition for fault identification
Test condition:
Engine start completed
Terminal condition: Terminal 15 ON
Voltage condition:
OBD1 conditions met (voltage between 10 V and 16 V)
Condition for fault memory entry
0.2 sec.
Action in service
1) Visual inspection of plug-in terminals (at components and
DME)
2) Perform electrical check on sensor wire, power supply
and ground
3) Replace sensor
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none