64 51 ... Leak-Testing Evaporator




64 51 ... - Leak-testing evaporator





Special tools required:
- 64 5 121 64 5 120 Test Adapter Set, A/C Components
- 64 5 124 64 5 120 Test Adapter Set, A/C Components






Warning!
It is essential, when handling nitrogen, to observe the standard national safety regulations.

Ensure that employees are advised of how to handle pressurized vessels and nitrogen correctly (danger of asphyxiation). For this purpose, follow the notes and instructions in the technical safety specifications available from the gas supplier.





Necessary preliminary tasks:
- Remove expansion valve Service and Repair





Replace sealing rings (1) and coat with refrigerant oil





Screw down special tool 64 5 124 64 5 120 Test Adapter Set, A/C Components with retaining clip (1).

Tightening torque 64 53 13AZ [1][2]Hose/Line HVAC.





Connect special tool 64 5 124 64 5 120 Test Adapter Set, A/C Components to special tool 64 5 121 64 5 120 Test Adapter Set, A/C Components.





Important!
Risk of damage: Use only nitrogen pressure bottles with pressure reducers for leak-testing.

Pressurize evaporator to 10 bar slowly only. Excessively fast pressurization and pressures in excess of 20 bar may cause damage to the evaporator.





Connect nitrogen pressure bottle with pressure reducer to pressure gauge and then connect to special tool 64 5 121 64 5 120 Test Adapter Set, A/C Components (connecting hose).

Note:
- Testing apparatus must be leakproof.
- Ambient temperature and temperature of vehicle must not change during the test procedure.
- Do not move the vehicle during this period

Apply test pressure of 10 bar slowly and close nitrogen pressure bottle.

Check leak-tightness of testing apparatus and of connection to refrigerant line.

Set test pressure of 10 bar is only permitted to drop by 2 bar to 8.5 bar over a test period of 1.5 hours.

If the pressure loss is greater than 1.5 bar, this indicates that there is a leak in the evaporator unit.





Warning!
After leak-testing, unscrew special tool 64 5 121 64 5 120 Test Adapter Set, A/C Components slowly from special tool 64 5 124 64 5 120 Test Adapter Set, A/C Components to reduce pressure.





After leak-testing:

- Replace all sealing rings and moisten with refrigerant oil