P00C0
122104 - P00C0Information saved in
DME
Fault code
122104 - P00C0
Fault text
Bypass blow-off valve 2, activation: open circuit
Fault description
The diagnostic function monitors the electrical connection
between the DME and compressor bypass valve 2.
Condition for fault identification
Test condition:
The fault is recognized when an open circuit is present
during activation of compressor bypass valve 2.
Potential problem source(s):
- Defect in wiring harness between DME and compressor
bypass valve 2
- No power-supply voltage to compressor bypass valve 2
- Diverter valve 2 defective
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- 0.5 sec.
Other conditions:
- Component must receive activation signal
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 1 sec.
Action in service
- Disconnect compressor bypass valve 2 and check the
wiring harness
- Check power-supply voltage to compressor bypass valve 2
- Replace compressor bypass valve 2
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: none
Service instruction
- none