67 62 020 Removing and Installing/Replacing Flat Motor For Rear Left or Right Power Window Unit
67 62 020 Removing And Installing/replacing Flat Motor For Rear Left Or Right Power Window Unit
Necessary preliminary tasks:
- Remove rear power window unit
Release screws (1), tightening torque 51 35 1AZ.
Detach flat motor for power window unit (2) in direction of arrow from power window unit (3).
Installation:
Fit flat motor for power window unit (2) exactly on teeth of power window unit.
Replacement:
A normalisation must be carried out in order to activate anti-trapping protection.
Operating sequence for normalisation:
- Operate corresponding power window switch in "Close" setting.
- Once the upper end position has been reached, hold power window switch down for approx. 1 second more.
If necessary, repeat procedure again.
Normalisation is thus completed.
NOTE: Carry out function check (one-touch function, anti-trapping protection and, if necessary, comfort function).