P14C6
2F10 - P14C6Information saved in
DME
Fault code
2F10 - P14C6
Fault text
Radiator blind, bottom
Fault description
Radiator Shutter (Lower) Electrical
Condition for fault identification
Test condition:
1. PKKS must be initialized.
Operation of lower flap:
3 x open and 3 x closed
Or conduct the system test
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
up to 20 sec.
Action in service
1. Check wire from AKKS PIN 4 to PKKS (connection +)
2. Check ground connection to the PKKS
3. Check retention solenoid (internal short or burned
through)
Fault effect and breakdown warning
Driver information
Warning light:
no external display;
Service instruction
none