P14C6

2F10 - P14C6

Information saved in
DME

Fault code
2F10 - P14C6

Fault text
Radiator blind, bottom

Fault description
Radiator Shutter (Lower) Electrical

Condition for fault identification
Test condition:
1. PKKS must be initialized.
Operation of lower flap:
3 x open and 3 x closed
Or conduct the system test
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V

Condition for fault memory entry
up to 20 sec.

Action in service
1. Check wire from AKKS PIN 4 to PKKS (connection +)
2. Check ground connection to the PKKS
3. Check retention solenoid (internal short or burned
through)

Fault effect and breakdown warning


Driver information
Warning light:
no external display;

Service instruction
none