P2089
2A80 - P2089Information saved in
DME
Fault code
2A80 - P2089
Fault text
Intake VANOS, activation
Fault description
'A' Camshaft Position Actuator Control Circuit High (Bank
1)
Condition for fault identification
Test condition:
Monitoring of VANOS control
Engine speed > 500 rpm
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
none
Action in service
1Check wiring
Repair if defective
If wiring is OK proceed
to check component
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction