Operation CHARM: Car repair manuals for everyone.

P1078

2A3E - P1078

Information saved in
DME

Fault code
2A3E - P1078

Fault text
Valvetronic, actuator motor: overload

Fault description
VVT-Overload Protection Control Motor Current High
Input (Bank 1)

Condition for fault identification
Test condition:
Monitoring of servo motor overload;
The VVT servo motor temperature is calculated in the DME
using a model. The first stage occurs when it heats beyond a
warning threshold (fault #10819, fault class 2). This is 190
°C (VVT motor temperature) and causes the VVT to revert
to operation in its emergency mode. If the VVT motor were
to overheat even further, the VVT system would be
completely deactivated upon reaching the deactivation
threshold (200 °C VVT motor temperature).
Terminal condition: Terminal 15 ON
Voltage condition:
none

Condition for fault memory entry
Warning threshold: 190 °C VVT Servo motor temperature
Deactivation threshold: 200 °C VVT servo motor
temperature

Action in service
1. Check VVT servo motor
2. Allow servo motor to cool, Clear fault memory and verify
that DME software is the most recent version
3. DO NOT replace DME!

Fault effect and breakdown warning


Driver information
Warning light:
ECE: No warning message. Engine reverts to VVT
emergency backup mode (throttled operation) US: OPEN

Service instruction
none