54 37 ... Gauging Coupling Fastener (After Removing and Installing Roof Module)
54 37 ... - Gauging coupling fastener (after removing and installing roof module)
Special tools required:
Important!
To prevent damaging the coupling fastener gauge, set the gauge down only in the transportation crate or on the cross beam.
The coupling fastener gauge is a highly sensitive measuring instrument which reacts even to light impacts with distortion.
The coupling fastener gauge must be checked for dimensional accuracy on a master gauge after being subjected to impact or dropped.
Note:
The coupling fastener must be gauged after each removal and installation of the roof module 54 37 130 Removing and Installing Roof Module.
Necessary preliminary tasks:
- Roof module 54 37 130 Removing and Installing Roof Module must be installed
- Align basic gauge Aligning Basic Gauge
Important!
Tape off corners of roof shell 1 and 3. Risk of damage when positioning gauge for coupling fastener and assembly.
Gauge, coupling fastener:
Note:
Coupling fastener must not be screwed into place for adjustment work (barrel screws move freely).
Slacken screw for rubber stop (1) and pull back.
Insert special tool 54 0 130 in coupling fastener.
Screw gauge for coupling fastener 54 0 131 on left and 54 0 132 right onto basic gauge with special tool 00 9 251.
Tightening torque: 6 Nm
Turn L-piece (2) under stop screw (3) of coupling fastener.
Adjust coupling fastener as follows:
Set stop screw (3) with adjusting screw (1) such that it comes up against stop (4).
- Stop screw (3) of the coupling fastener is aligned flush at stop (4)
- The L-piece (2) should ideally rest against the gauge
Bring barrel screws into contact with special tool 54 0 180 in conjunction with 00 9 450.
Tightening torque: 0.2 Nm (=20 cNm).
Installation Note:
Observe screwing sequence of coupling fastener:
Refer to Installing roof module 54 37 130 Removing and Installing Roof Module.
1. Z-direction (coupling fastener to screwing plate, rollover protection system)
2. Y-direction (coupling faster to side panel)
3. X-direction (roof frame to partition wall)
Tightening torque: 54 37 22AZ 54 37 Power Convertible Top.