Air Flow Meter/Sensor: Service and Repair
13 62 560 Removing and installing/air-mass flow sensor (M57T2)
Necessary preliminary tasks:
- Read out fault memory of DDE control unit; if necessary, work through test schedules
- Switch off ignition
- Remove acoustic cover
Release bolts (1).
Unclip line (2).
Detach intake pipe (3) in direction of arrow.
Unlock plug connection (2) on air-mass flow sensor and disconnect.
Release bolts (1).
Remove air-mass sensor.
Tightening torque 13 62 7AZ.
Now clear the fault memory.
IMPORTANT:
EU4 only.
Reset adaptations, quantity mean value adaptation