P00A2
108B02 - P00A2Information saved in
DME
Fault code
108B02 - P00A2
Fault text
Charge-air temperature sensor 2, electric: short circuit to
ground
Fault description
The diagnostic function monitors the lower voltage limit on
the charge-air temperature sensor on Bank 2.
Condition for fault identification
Test condition:
The fault is recognized when the sensor voltage of the
charge-air temperature sensor 2 is < 0.1 V.
Potential problem source(s):
- Defect in wiring harness
- Charge air temperature sensor defective
Terminal condition: Terminal 15
Voltage condition:
- None
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 2.5 sec.
Action in service
- Visual examination of plug-in contacts (at component and
DME ends) Perform electrical measurements on sensor wire,
power supply and ground (possible intermittent open!)
- Replace sensor
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Slight reduction in power
Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: none
Service instruction
- none